Sensorex - CX2000 Conductivity Transmitter/Controller
Model #: 999-543-021
*Prices are subject to change without notice
The Sensorex CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.
Standard delivery is 1-2 weeks but typically will ship sooner.
Product Description
The Sensorex CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.
Benefits:
- Reliable process control: Two (2) adjustable Hi/Lo relay contacts
- Lightning fast sensor calibration: Preset standards make sensor calibration quick and simple
- Perfect for use in all environments: LCD display with auto-sense backlight technology & NEMA 4X, IP65 enclosure
- Compatible with a wide variety of sensors: For use with all Sensorex contacting conductivity sensors
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Note: CX2000 Conductivity Controller and 4-20mA transmitter is compatible with sensors with tinned lead connectors and either 30k NTC or Pt1000Ω RTD temperature compensation.
Product Features
- Measuring Range:
- Conductivity: 0.000 uS/cm -200.0 mS/cm in 5 ranges 0.01/.01/1 uS/cm, 0.01/0.1mS/cm resolution, +/-1% Accuracy (+/- 1 digit)
- Resistivity: 0.00-20.00 MΩ • cm, 0.01 MΩ • cm resolution, +/-1% Accuracy(+/- 1 digit)
- Temperature Range: -30 °C to 130 °C, 0.1 °C resolution, 0.2 °C accuracy
- Calibration Mode: Automatic with built-in standard solutions manual cell constant adjustment
- Cell Constants: 0.01, 0.05, 0.1, 0.5, 10/cm fixed or freely selectable 0.0080 - 19.99/cm
- Analog Output 1: Isolated DC 0/4 -20mA, corresponding to conductivity or resistivity. Max load 500 Ω.
- Analog Output 2: Isolated DC 0/4 -20mA, corresponding to temperature output. Max load 500 Ω.
- Set-Points:
- Contact: 240V AC, 5A max
- Activate: setpoints Hi/Low, Hi/Hi, Low/Low, ON/OFF
- Enclosure: NEMA 4X IP65, with push-button control pad. HWD: 96 mm (3.77”) x 132 mm (5.20”), 1/4 DIN
- Panel Cut-Out: 93mm (3.66”) x 93mm (3.66”)
- Weight: approximately 0.50 kg (1.1lb)
- Mounting Options: Panel or Wall Mount
- Ambient Temperature: -0 ° C to 50 ° C
- Storage Temperature: -10 ° C to 70 ° C
- Temperature Compensation: NTC 30K or Pt1000 RTD with automatic compensation or manual
- Temperature Coefficient: Linear comp 0.00-40.00%, Non-linear comp for natural waters
- Power requirement: 100-240V AC +/- 10%, 5W max, 50/60 Hz
Product Applications
- Conductivity
- Controller
- Transmitter
- Cooling Tower
|
|
|
|